A-A-51183A
3.6 Nameplate. A nameplate shall be securely attached to the power source. Unless otherwise specified (see 7.3(q)), the nameplate shall contain the following information:
a. Nomenclature.
b. Manufacturer's name. c. Serial number.
d. Machine model designation.
e. Power input (volts, total amperes, phase, frequency). f. Short-circuit/over-current rating.
g. Contract number or order number. h. National stock number.
i. Date of manufacture.
4. REGULATORY REQUIREMENTS
4.1 Recovered materials. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR).
4.2 Environmental protection. The power source shall meet all applicable Environmental Protection Agency (EPA) restrictions in effect on the date of the contract. These regulations apply to the emission of materials hazardous to the environment or the user's health and shall be adhered to during the manufacturing, service, transportation, storage, and operation/use of the item.
5. PRODUCT CONFORMANCE PROVISIONS
5.1 Product conformance. The power source shall meet the salient characteristics of this commercial item description; conform to the manufacturer's own drawings, specifications, standards, and quality assurance practices; and be the same product offered for sale in the commercial marketplace. The Government reserves the right to require proof of such conformance.
5.2 Inspection. The power source shall be inspected to determine compliance with all requirements specified in this CID.
5.3 Testing. Unless otherwise specified (see 7.3(r)), the power source shall be tested in accordance with sections 5.3.1 through 5.3.3.
5.3.1 Test setup and conditions. Unless otherwise specified (see 7.3(s)), the manufacturer shall be responsible for supplying all tooling and material(s) and shall conduct all tests required by the Government. The manufacturer shall provide test instruments and equipment with calibration traceable to National Institute of Standards and Technology (NIST) and shall provide
certification of calibration as specified (see 7.3(t)). Unless otherwise specified (see 7.3(u)), the machine shall be tested in accordance with environmental conditions specified in IEC 60974-1.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business